p440ar firmware. For more information, see "Power fault LEDs. p440ar firmware

 
 For more information, see "Power fault LEDsp440ar firmware  Download the latest firmware and drivers to optimize its performance and reliability

0; using interactive mode, deselect the firmware version 4. You will also find the release notes. Just because you bought it used, doesn't mean it wasn't still under warranty. For the server you have, RHEL 6. HPE SSACLI – License key. 00) in slot 0 (embedded RAID) and a P840 controller (FW ver 2. Running firmware: 8. At the iLO main menu, the options are to either Configure and Install – which provides a “wizard” to perform a clean install and system reset to defaults – or Perform Maintenance , where you can delete or add drives on existing RAID disks. None of this will harm data on disk or RAID config on the controller. Offers integrated 2 GB DDR3-1866 Flash Backed Write Cache providing up. HPE ProLiant DL/ML/BL Server - How to Upgrade/Downgrade Controller Firmware from BIOS. 88?) what does 0 mean? I searching the whole HPE download center and did not found it. 04. 04. 4LFF drive configuration — Connect the 4LFF Mini-SAS cable to the P440ar controller. Smart Path requires updated firmware, drivers, and configuration utility available at: HPE SSD Smart Path is ideal for read intensive. HP DL360 with a HP SmartArray P440ar in HBA mode with four HP SSDs. O/S VMWare 5. RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Messages. O/S VMWare 5. 0. To use HP P440ar controllers with the GA release of ESXi 6. You will also find the release notes. Learn more about SUM. "no persistent storage" message appears, and all. Flashing blue The drive carrier firmware is being updated or requires an update. 4 TB - hot-swap - 2. 04 is not available. The HPE SimpliVity Support Pack provides a comprehensive firmware update for all HPE SimpliVity Gen9 and Gen10 servers. ESXi 6. for testing purpose i use 2 HP DL380 Gen 9 servers , i had some problems getting the disks to be recognized as SAS in Windows Server , but after a bit of google time i found out that after deleting all of the RAID config's on the HP P440ar and putting it into HBA Mode , it is possible. Find the right HPE Smart Array P440ar Controller for your HPE ProLiant Gen9 server. exe) The. HPE ProLiant DL380 Gen9 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product. • English, French, German, Italian, Japanese, Simplified Chinese, and Spanish languages are supported. Hmmm. 2. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. However, the cabling for the P440ar controller remains the same. HPE Technology Service Portfolio. The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs),. To use HP P440ar controllers with the GA release of ESXi 6. 0. . It features eight internal physical links and delivers increased. Use the HP Smart Storage Utilities for Linux to modify the RAID configuration within the host OS. bin. Insert new drives and create new RAID10 array. ProLiant DL360 Gen9 with HP Smart Array P440ar Controller. 2. Part Description. May 13, 2021. Smart Array P440ar in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: PDNLH0BRH753PJ Cache Serial Number: PDNLH0BRH753PJ RAID 6 Status: Enabled Controller Status: OK Hardware Revision: B Firmware Version: 7. At the iLO main menu, the options are to either Configure and Install – which provides a “wizard” to perform a clean install and system reset to defaults – or Perform Maintenance , where you can delete or add drives on existing RAID disks. 73. Get the latest software, documentation and support from HPE. 0 build-5310538. 5 to 6. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. It's nothing more than a low-end. In this server, HPE SSA can be accessed in. Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. Customer Resources. New comments cannot be posted. Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. Option 2 sounded much better. 24SFF drives at the front and 2SFF drives at the rear of the server — Connect the P440ar controller cables to the 12G SAS Expander port 1 and port 2. Firmware | SATA Storage Disk. 11 unfortunately. 52. HPE DL380 Gen9 P440ar/H240ar Riser 2 SAS expander kit. Open chassis, ESD ground yourself on the side of the chassis, remove the SAS cabling from the P440ar, and then remove the p440ar, and unplug the battery from the board. Find the latest firmware, drivers, software and utilities downloads for current generation Intel® RAID/Storage products below. • Applications can be executed using the following tools: o Any bootable media, such as a software CDHPE iLO (Firmware HPE iLO4 2. Before upgrading, read this important information. . (Still updating the HP bits, the iLO4 firmware update had a glitch of some kind. 5" disks aren't that large in capacity, so you wouldn't be running into issue with that anyway. Proactive notifications; Service Pack for ProLiant. Can I just purchase the controller and replace it. Remove drives used in data array and hot spare, and label with their positions. HPE ProLiant Gen9 Server - HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter: Resetting to Factory Defaults. exe) - Operating System : Windows Server 2012 R2 - SmartArray Driver : HPE ProLiant SmartArray HPCISSS3 controller driver version 106. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. for HPE ProLiant DL, ML and Apollo Servers. 7 on its firmware site. 0. Expands storage capacity in an array or change RAID levels. 4. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. In this server, HPE SSA can be accessed in. Last Recommended or Critical Version: 6. Get support for this product . 0 build-5310538. Hewlett Packard Enterprise Support CenterHPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 52. A new version of firmware can be flashed to the ROM while the c ontroller maintains the last known working version of firmware. 1. /ssacli ctrl slot=5 lk. HP is still investigating root cause. 00 - cp039995. 52, Hardware Revision: B. 0Gbps link speeds, even if they're 6G drives. then upgrade the firmware to lastest version. This can be done with the following command: # License key installation . QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. 3. We would like to show you a description here but the site won’t allow us. 15(B) 2023-07-06. 5. 04,. 0 using HP install ISO in both cases (comes bundled with drivers, etc). 0 with HPE Smart Array p440ar - after Smart Array firmware update - STORAGE LOST. 7. 10. The HDD are 10k RPM, 12GB SAS, 1. Installing the firmware-linux-nonfree package solves this issue (not sure if not installing it penalizes the CPU too much though). Problematic firmwares include 2. 0Partner Ready program Partner Ready Vantage program Find a Partner Certifications HPE GreenLake Marketplace. Product Support Software & Drivers Warranty Check Enhanced Support Services Education and Training Product Return and Recycling OEM Solutions Validate Equipment Parts. All firmwares were updated to their most recent versions, so I believe that utility was also most recent version. Support. Patrol readI am having problems installing Debian 7. . 20 Last Recommended or Critical Version: 7. HPE CS700 2. Yes it is a custom HPE/PMC Sierra design, > microsemi > MicroChip. Activity ring Rotating green Drive activity. 0, use one of these options. This procedure worked as expected. 摘要. HPE ProLiant DL/ML/BL Server - How to Upgrade/Downgrade Controller. 2TB SAS 12G Enterprise 10 K SFF. The controller has been tested with firmware 3. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. 5. 00 Previous Version of Firmware: 6. The latency is shown by the HPE Dual MicroSD where is Esxi running on it. Option 2 sounded much better. Navigate to the Virtual SAN cluster in the vSphere Web Client. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. 0 Link Detected: true Link Status: Up Name: vmnic0 PHY Address: 0 Pause Autonegotiate: true Pause RX: true Pause TX: true Supported Ports: TP Supports Auto Negotiation: true. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. 00 - cp039995. View Profile View Forum Posts View Forum Threads Visit Homepage. It features eight internal physical links and delivers increased server. Creates and sets up HPE SmartCache to accelerate. They all behave similarly. may have older product names and model numbers that differ from current models. Boot up the server and acknowledge errors about failed drives. Data Availability, Protection and Retention. fw" in same, Now save the file as an img format and mount the same to flash further. HPE SSACLI – License key. When the update tool is run it will indicate firmware versions currently installed on the server. 03 (or earlier) is updated to v2. Embedded Flash/SD-CARD Controller firmware revision 2. Proactive notifications; Service Pack for ProLiant. Service Pack for ProLiant. This reduces the risk of flashing firmware to the controller. Learn more at the Official Hewlett Packard Enterprise Website. Download Software. 02(B). The HPE Smart Array SR Gen10 Controllers for the ProLiant DL and ML Gen10 Servers and Apollo Gen10 Servers, supporting 12Gb/s SAS and PCIe 3. ESXi 6. User feedback and latest news. Format new array and restore data from tape backup. HP Smart Array P440ar controller: Device Type : SAS: DID : 3239: Brand Name : HP: SVID : 103c: Number of Ports: 8: SSID : 21c0: VID : 103c: Notes: Firmware versions listed are. Are you looking for the latest software and firmware updates for your HPE Smart Array P440ar Controller? Download them from this webpage, where you can also find installation instructions, release notes, and compatibility information. Install the host using HP's custom ESXi 6. Firmware Version : 4. 0. If the new controller is to be the boot device, install the device drivers ("Installing device drivers" on page 19). Urgend - DL380G9 / ILO says: Failure of HP Smart Array P440ar Firmware 3. The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. (enabling HP SSD smart path didn't bring a performance improvement btw. Open Power ISO software and click on New --> hard disc image (last option) Now add firmware file "HPE_luxor. 32 Firmware Supports Online Firmware Activation: False Wait for Cache Room: Disabled. " Select the appropriate operating system. 10. I'll add that you should avoid consumer SSDs for this purpose, and possibly try to avoid SATA devices if you can. 09. HPE ProLiant DL388 Gen9 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 2 SSD Enablement Board option. HPE Smart Array P440 Controller. Service Pack for ProLiant. This x64 Smart Component provides firmware for the following storage controllers: Smart Array H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440. el ‎20-12-2019 09:40 AM. . Communities. 26. The Smart Storage Admin said rebuilding but then rebuild failed - failed on the P440ar side. " Locate, download, and install Smart Array Firmware Version 4. ago. The HP smart array P440ar Raid controller failed on a server and I can no longer see the logical drives. Learn more at the Official Hewlett Packard Enterprise Website. HPE Integrated Lights-Out 4 (iLO 4): Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Universal media bay cabling. And every 8 hdd's connected is green/ok. 7, and configured with any of the following HPE Smart Array Controllers with smartpqi Driver version affected: 1. 00-1. 2. 52. The HPE Smart Array P440ar Controller is a Flexible Smart Array, 12Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for specific HPE ProLiant Gen9 rack and tower servers. The secondary problem is that you're still dependent on the RAID card firmware surviving, and ZFS is known to place a huge workload on it - a RAID card torture test. May 13, 2021. 00: Recommended: Firmware - Storage Controller: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p,. iLO4 has been updated and the new P440ar is running the latest firmware, any advice here please would be appreciated. IMPORTANT: Always perform a backup before installing or updating device drivers. tried to hyperv freenas but very poor performance. 03 (or earlier) is updated to v2. Option Part Number. The update fixes a. Rear serial port option. QuickSpecs HPE Smart Array P440 Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 1 x8 internal port o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libraries • 4 GiBytes. Reboot the host & perform a scan and walah. HPE ProLiant BL460c Gen9 Server Blade: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 06 is not supported for vSAN on P440 nor P440ar, nor is driver 6. Before SATA, hotplug was one of the reasons people bought hardware RAID -- one of the common failure modes for software RAID was disks failing during the power cycle and reboot from a degraded RAID that you needed to swap an IDE drive, and that's where the reputation of software RAID as unreliable comes from. This document provides step-by-step instructions, screenshots, and troubleshooting tips for common issues. Printer Setup, Software & Drivers; Printing Errors or Lights & Stuck Print Jobs; DesignJet, Large Format Printers & Digital Press; Sprocket; Samsung; Printers Knowledge Base; Printer Wireless, Networking & Internet; Printer Ink Cartridges & Print Quality; Printer Paper Jams & Feed Issues; Desktops Desktop Software and How To. Online ROM Flash Component for VMware ESXi - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. Open comment sort options. 7 for example) but from experience I know that in 99%, those. P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 version 5. even upgraded to 6. HPE ProLiant ML10 Gen9 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. The P440ar controller with cut heatsink allows for clearance when a GPU is installed in the secondary full height riser cage. The other bootable side rebuild went perfect. QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. HP Proliant DL380 G9 / HPE Smart Array P440ar Controller: not detected intermittently. Search the support knowledge base, download drivers and patches, create and manage cases, and learn from expert users in forums. What does this warning mean, do I have to worry about. The next piece of firmware to execute might actually be the firmware of the Smart Array P440ar Controller. 3. Chose Embedded RAID 1: Smart Array P440ar controller. The HP Smart Array P440ar RAID is embedded with the SSD Smart Path feature, which enhances the read performance SSD disk. Software, firmware, and utilities. BenefitsUpdate the server firmware ("Methods for updating the firmware" on page 12). 5. 2 SSD Enablement Board. Showing 1 of 1. 5. Functionally, the other. 0. Small and Midsize Business Networking. /ssacli ctrl slot=5 lk. Product Bulletin, research Hewlett Packard. Thanks for your help!IT Configuration is the following : - Server ProLiant ML350 Gen9 E5-2620v3 2. 00) and renewed the battery. processors. 1. HPE Flexible Smart Array P440ar/2GB QuickSpecs HPE ProLiant ML350 Generation9 (Gen9) Standard Features DA - 15035€€€Worldwide QuickSpecs — Version 10 — 12/1/2015 Page€7. We were hoping to use only the HBA mode of the P440ar Smart Array controller for all disks. 03. VGA is Radeon, and complains about the firmware missing (no acceleration, reduced 2D performance). Firmware - Storage Controller. Una pregunta en el momento tengo el siguiente aviso en. 概要. HP's compatibility matrix states the certified operating systems and minimum versions needed to operate on a given hardware platform. Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. The Current Supported Version is the version currently provided by this HP FUP Release. Operating System: Linux. The update fixes several issues and improves the stability and performance of the controller. 5. 52 is included in the Service Pack for ProLiant (SPP) Version 2016. So I installed latest version 4. Another difference could be the Linux kernel version perhaps? Then again, I'm running 4. 00. Overview 6 Using HP SSA over other configuration utilities provides the following benefits: • GUI, CLI, and Scripting interfaces are available. RoHS. Video review of the model and its features. Increased Performance for Applications. 0. Using a web browser, connect to the iLO web interface using the iLO IP address or PQDN/FQDN. After conducting a very thorough investigation, HPE and the vendor are confident that they have identified the root cause of the issues and on August 11, 2020, HPE released HPE. Reboot the server and press F9 at post to enter into system utilities --> Embedded Applications --> Firmware update --> Select installed Smart Array. 24 Serial Number: *snip* Rebuild Priority: Medium. 4 Ghz - HP SmartArray P440ar (firmware version 7. 15(B) 2023-07-06. 2 SSD Enablement Board option cabling; Software, firmware, and utilities. 0 provides the following features: • RAID 6 (ADG) • RAID 60 • Advanced Capacity Expansion • Mirror splitting and recombining in offline mode • Drive EraseWe would like to show you a description here but the site won’t allow us. HPE Smart Array P440ar Controller cabling; HPE Smart Array P840ar Controller cabling; Universal media bay cabling; 150W PCIe power cable option; M. Verify operating system support—For information about operating systems supported by ProLiant servers, see the. . Detected operating system: Choose a different OS . Release Device Driver Firmware Package Version Firmware Version Queue Depth Driver Type vSAN Type FeaturesAnd points out a problem with HP's software. With 4 times the better SSD read performance in the HP smart array P440ar RAID controller, the HPE Solid-state drive Smart Path chooses the right path to the SSD and then it accelerates the reads for all the RAID levels. Hey all, I have an ESXi 5. HPE ProLiant DL/ML/BL Server - How to Upgrade/Downgrade Controller Firmware from BIOS. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Choose Exit and Launch HP Storage Administrator. I've installed a recent Debian 10 Buster system on to the server, which is HPE DL360 Gen9. Proactive notifications. Release Date. of 33. from time to time, the smart array freeze and the fans produce an excessif noise. 04), upgrading iLO 4 to 2. -Check current firmware-Locate newest firmware from vendor-Upload firmware-Reboot Open-E DSS V7Storage software that gets the job done: · Data Protection and Recovery Software. Learn how to install, configure, and use the HPE iLO 5 web interface, a remote server management tool that simplifies server administration and troubleshooting. if the second point applies, where I can find a version I can put on a USB and install over the BIOS? All I can see is Windows software or Rehat files. Download PDF. for HPE ProLiant DL, ML and Apollo Servers. PaSha_no • 1 yr. 5. Firmware Upgrades of DL 380 Gen9 . I've tried h730 [and h740] in a test rig, and they seem to. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. It was working fine, then I have updated the HP Smart Array P440ar firmware, rebooted the host (twice), and the same command which was working before. Share Sort by: Best. The iLO firmware version has already been displayed, so the firmware module related to the initialization of the iLO functionality is probably already successfully executed. 1. To proceed, upgrade the firmware in steps. Drum roll. Locked post. 1. upgrading the smart array controller (P440ar) firmware to the latest version (5. Learn how to update the iLO firmware of your HPE server using the HPE Service Pack for ProLiant (SPP) and the Smart Update Manager (SUM) tool. After performing these. Hewlett Packard Enterprise support portal for business, enterprise and IT users. The document also includes installation instructions, configuration. Whether you're a large enterprise or a smaller business, Hewlett Packard Enterprise data protection and recovery software will cost-effectively protect you against disaster and ensure business continuity. Offers integrated 2 GB DDR3-1866 Flash Backed Write Cache providing up. After the firmware upgrades we restarted the server, ESXi booted up, but. For more information, see "Power fault LEDs. Both hardware raid card have the latest firmware, so as the SAS expander cards and the rest of the server overall (used the latest iso firmware image available from HP). Expected Behavior. Here is the config: Text => ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: P61620F9VV6I1I Cache Serial Number: PA2270H9VV538J RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware. On-Line Spares: There is no limit to the number of spare drives that can be installed prior to drive failure. 0 x8 RAID controller that provides enterprise-class storage performance, increased internal scalability, and data protection for HPE ProLiant DL360 and DL380 Gen9 rack servers. Eliminating most of the hardware RAID controller components, and relocating advanced RAID algorithms from a hardware -based controller into device driver software lowers the total solution cost, while still maintaining comparable RAID protection and full compatibility with SmartHPE CommunityOnline HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives. Open all. I have the P440ar connected to the risers on the front of the system, and I'm starting off the P840 6. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. The iLO firmware version has already been displayed, so the firmware module related to the initialization of the iLO functionality is probably already successfully executed. So I installed latest version 4. We are planning to run TrueNAS as storage provider as well as hypervisor to contain all business VMs and a shared directory for branch offices. Get it Nov 3 - 8. However, you should be aware that SATA disks on that controller will downshift to 3. LG Spirit LTEH440N. A new version of firmware can be flashed to the ROM while the controller maintains the last known working version of firmware. thanks, Kev If you are looking for the latest software for your HPE Smart Array P440 Controller, you can download it from this webpage. HPE Smart Array P440ar Controller cabling. The HPE Smart Array P440ar Controller is a Flexible Smart Array, 12Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and. - p440ar make the fans sound like a rocket. 04) And the same for the Wellsburg AHCI controller. 0 Custom Image, download the ISO from VMware downloads and install. Use AHCI SATA mode instead. It features eight internal physical links and delivers increased server uptime by. Showing. Before putting server in the production, it’s always smart to update firmwares of all the components in the box, like P440ar RAID controller’s firmware, Bios, Power Management and so on. 4TB 10000RPM 2. Click the Flash button. 03. for testing purpose i use 2 HP DL380 Gen 9 servers , i had some problems getting the disks to be recognized as SAS in Windows Server , but after a bit of google time i found out that after deleting all of the RAID config's on the HP P440ar and putting it into HBA Mode , it is possible. In this video I'm preparing my storage server by updating the HP P420 firmware using a storage pack. 2 SSD Enablement Board option cabling. Dec 28, 2021; Thread Starter #6Advisory: (Revision) Cache Module May Become Permanently Disabled After Smart Array Firmware Upgrade to a Version Earlier Than 6. Hewlett Packard Enterprise support portal for business, enterprise and IT users. 56, a few days ago. 52-6. of 14. Software / System Requirements.